BT 214.2
- Open type or enclosed
- IP23 protection (others to order)
Application
- Grid-tied PV
- Elevators and motor pumps
- Cables up to 300 m
- Regenerative braking
Technical details — BT 214.2
The drive's PWM distorts the sine wave, heats the motor and reflects voltage onto the IGBTs. Cables >3 m increase the overvoltage at the terminals.
Why use one between drive and motor
- Attenuates PWM harmonic distortion
- Limits voltage peaks on the IGBTs
- Reduces leakage current and ground-fault trips
- Protects stator insulation on long cable runs

Technology
- Thermal protection thermostats
- Linear reactors for sinusoidal filters
- Metallized polypropylene capacitors — 135,000 h