What is a harmonic filter?
A harmonic filter (also called a harmonic distortion filter) reduces current or voltage components at multiples of 60 Hz — the harmonics — generated by nonlinear loads: variable-frequency drives, rectifiers, induction furnaces, LED lighting, UPS systems, chargers and PV inverters.
Without mitigation, THD (Total Harmonic Distortion) rises: cables and transformers heat up, capacitors fail, protection trips and the plant may fall outside the limits of IEEE 519 and PRODIST (ANEEL). A harmonic filter tackles the cause, in the distorted current/voltage — it does not just “mask” reactive power.
For harmonics and power quality concepts in plain language, see also the power quality and harmonics guide.
When does a plant need a harmonic filter?
Typical signs that it is worth investigating (with Class A measurement):
- Capacitors that burst or trip frequently
- Hot transformers or cables with no apparent kW overload
- Reactive energy penalties (UFER) on a network with many drives/LED/solar
- Circuit breakers or protection that trip “for no reason”
- Contractual or utility requirement (RISE / compliance)
Important: a capacitor bank alone, on a network with harmonics, can worsen THD through resonance. That is why Dicel addresses PFC and harmonic filters in the same assessment.
Types of harmonic filter: passive, active and hybrid
Detuned passive filter
LC circuit tuned to attenuate harmonics and, in many designs, correct PF at the same time. Robust and economical for stable loads.
View passive filter range →Active filter (AHF)
Compensates harmonics dynamically. Suited to cases where the spectrum varies widely with production.
Passive vs active →Hybrid solution
Combines passive + active, or detuned PFC + AHF, when the plant requires both.
When to use hybrid →Other related solutions in the Dicel catalog: LC sinusoidal filter for drives, EMC/EMI filters, capacitor banks (PFC) and detuning reactors.
Harmonic filters by application
Each type of load calls for a different filter. In Dicel's detuned passive range:
- Variable-frequency drives, elevators and switch-mode power supplies — filters for AC/DC converters, up to 1000 kW
- Induction furnaces — detuned filters from 475 to 1500 V
- Plants with many loads — FHT automatic filter bank, from 0.1 to 1.4 MVAr
- Local correction — compact filters from 2 to 72 kVAr with power factor correction
- Lighting with ballasts — filter for up to 12 gas-discharge lamps
- Homes and small businesses — residential filter with power factor correction
Between the drive and the motor the problem is a different one (PWM and voltage peaks): that is where the LC sinusoidal filter comes in.
Standards: IEEE 519, PRODIST and RISE
Specifying a harmonic filter without looking at standards and measurements is guesswork. Dicel works with:
- IEEE 519 — current and voltage distortion limits at the point of common coupling
- PRODIST Module 8 — power quality in Brazil; the basis for RISE
- Class A measurements — spectrum up to high orders, events and reports
Use the free calculators (IEEE 519, UFER, PFC) and, for a field report, measurements and RISE.
How Dicel sizes a harmonic filter
- Understand the problem — downtime, penalties, capacitor failures, utility requirements
- Measure — Class A power quality when needed
- Choose the topology — passive, active or hybrid
- Specify and document — technical bulletins, PFC and compliance
- Follow up — consulting and, where applicable, in-company training
Based in Porto Alegre (RS) since 1982, Dicel is part of Grupo Singel and serves industry and infrastructure in Brazil, Argentina and Paraguay.